1.
Arq. bras. cardiol ; 116(5): 908-916, nov. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1248912

ABSTRACT

Resumo Fundamento: Nas últimas décadas, o número de dispositivos eletrônicos cardíacos implantáveis (DCEI) aumentou consideravelmente, assim como a necessidade de remoção destes. Neste contexto, a remoção percutânea apresenta-se como uma técnica segura e capaz de evitar uma cirurgia cardíaca convencional. Objetivos: Primário: descrever a taxa de sucesso e complicações da remoção percutânea de DCEI em um hospital público brasileiro. Secundário: estabelecer preditores de sucesso e complicações. Métodos: Serie de casos retrospectiva de todos os pacientes submetidos à remoção de DCEI em um hospital público brasileiro no período de janeiro de 2013 a junho de 2018. Remoção, explante e extração de eletrodos, complicações e desfechos foram definidos conforme a diretriz norte-americana de 2017. Variáveis categóricas foram comparadas pelos testes Qui-quadrado ou Fisher, enquanto variáveis contínuas, por testes não pareados. O nível de significância adotado nas análises estatísticas foi de 5%. Resultados: 61 pacientes foram submetidos à remoção de DCEI, sendo 51 extrações e 10 explantes. No total, 128 eletrodos foram removidos. Taxa de sucesso clínico foi 100% no grupo do explante e 90,2% no da extração (p=0,58). Complicações maiores foram encontradas em 6,6% dos pacientes. Falha do procedimento foi associada a eletrodos de ventrículo (p=0,05) e átrio (p=0,04) direito implantados há mais tempo. Duração do procedimento (p=0,003) e necessidade de transfusão sanguínea (p<0,001) foram associadas a maior índice de complicação. Conclusão: As taxas de complicação e sucesso clínico observadas foram de 11,5% e 91,8%, respectivamente. Remoções de eletrodos atriais e ventriculares mais antigos estiveram associados a menores taxa de sucesso. Procedimentos mais longos e necessidade de transfusão sanguínea foram associados a complicações.


Abstract Background: In the last decade, the number of cardiac electronic devices has risen considerably and consequently the occasional need for their removal. Concurrently, the transvenous lead removal became a safe procedure that could prevent open-heart surgery. Objective: The primary objective of this study was to describe the successful performance and the complication rates of pacemaker removals in a Brazilian public hospital. Our secondary aim was to describe the variables associated to successes and complications. Methods: A retrospective case series was conducted in patients submitted to pacemaker removal in a Brazilian public hospital from January 2013 to June 2018. Removal, explant, extraction, success and complication rates were defined by the 2017 Heart Rhythm Society Guideline. Categorical variables were compared using x2 or Fisher's tests, while continuous variables were compared by unpaired tests. A p-value of 0.05 was considered statistically significant. Results: Cardiac device removals were performed in 61 patients, of which 51 were submitted to lead extractions and 10 to lead explants. In total, 128 leads were removed. Our clinical success rate was 100% in the explant group and 90.2% in the extraction one (p=0.58). Major complications were observed in 6.6% patients. Procedure failure was associated to older right ventricle (p=0.05) and atrial leads (p=0,04). Procedure duration (p=0.003) and need for blood transfusion (p<0,001) were associated to more complications. Conclusion: Complications and clinical success were observed in 11.5% and 91.8% of the population, respectively. Removal of older atrial and ventricular leads were associated with lower success rates. Longer procedures and blood transfusions were associated with complications.


Subject(s)
Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable , Brazil , Retrospective Studies , Treatment Outcome , Device Removal
2.
Insuf. card ; 4(2): 73-76, abr.-jun. 2009. ilus
Article in Spanish | LILACS | ID: lil-633341

ABSTRACT

La endocarditis, relacionada con la infección del cable del resincronizador cardíaco, es una complicación rara asociada a los marcapasos endocavitarios. La incidencia de endocarditis que aparece tras el implante de un marcapasos endocavitario permanente oscila entre el 0,13% y el 7,9%. La historia natural de la infección en algunos casos es sombría, con un porcentaje de mortalidad alto, entre un 30-35%, según diferentes estudios. A continuación se presenta el caso de una paciente con endocarditis en el cable de un resincronizador implantable en la que no fue necesaria la extracción del mismo.


Endocarditis related to infection of the endocavitary wire is a rare complication associated with pacemakers endocavitaries. The incidence of endocarditis that appears after the implantation of a permanent endocardial pacemaker ranges between 0.13% and 7.9%. The natural history of infection in some cases is grim, with a high mortality rate, between 30-35%, according to various studies. We present a patient with endocarditis associated to a resynchronization wire in which it was not necessary its removal.


A endocardite relacionada com a infecção do cabo-eletrodo do ressincronizador cardíaco é uma complicação rara associada aos marcapassos endocavitários. A incidência da endocardite que aparece após o implante de um marcapasso endocavitário permanente oscila entre 0,13% e 7,9%. A história natural da infecção em alguns casos é sombria, com uma alta porcentagem de mortalidade, entre um 30-35%, segundo diferentes estudos. A seguir apresenta-se o caso de uma paciente com endocardite no cabo-eletrodo de um ressincronizador implantável em que não foi necessária a extração do mesmo.


Subject(s)
Pacemaker, Artificial , Endocarditis , Infections